JAB Detektor temperature, BUS JA-111TH View larger

Temperature detector JA-111TH

JA-111TH

New product

JABLOTRON ALARMS S.A.

The JA-111TH is a BUS temperature detector for JABLOTRON 100. It measures ambient temperature (-20…+70 °C), forwards readings to MyJABLOTRON, supports PG output heating control and includes an antifreeze function.

More details

Data sheet

Connection method BUS

More info

Product overview

The JA-111TH is a BUS temperature detector designed for seamless integration with the JABLOTRON 100 system. It measures ambient temperature and regularly forwards readings to the MyJABLOTRON cloud service for storage, graphing and automation.

Control and notifications: MyJABLOTRON can be configured to control heating by switching a programmable (PG) output on the control panel based on measured temperature. The system can send notifications by e‑mail or SMS when configured temperature limits are exceeded. Reliable external connectivity (GSM and LAN communicator) is required for guaranteed remote PG control; PG switching cannot be guaranteed in case of external communication failure or server outage.

Antifreeze and thermostat behaviour: the detector provides a fixed antifreeze function (nominal +6 °C, ±1 °C hysteresis); activation occurs at approximately +5 °C and deactivation at approximately +7 °C. Thermostat responses and PG control behaviour can be set in MyJABLOTRON or via the control panel settings.

Installation and placement: the unit occupies one BUS address and should be installed where it will measure representative room temperature (avoid heaters, ventilation outlets and direct sunlight). Readings are archived (e.g. every 5 minutes) and can be visualised and analysed in MyJABLOTRON.

Technical data:

  • Power: BUS 12 V (9…15 V)
  • Current consumption (standby): 5 mA
  • Dimensions: 55 × 27 × 16 mm; weight: 12 g
  • Measurement range: -20 °C to +70 °C; accuracy: ±0.5 °C
  • Antifreeze: +6 °C (±1 °C hysteresis; activation ≈ +5 °C, deactivation ≈ +7 °C)
  • Enables PG output control from MyJABLOTRON (up to 2 thermometers per control panel can control the PG output)
  • Designed for JABLOTRON 100; complies with EN 50130-4, EN 55022

The JA-111TH should be installed and configured by a qualified technician according to the manufacturer's installation instructions and the control panel manual.